Leave Your Message

China Suppliers Factory 90° Short Radius Elbow Industrial Insulation Pipe Fitting Covers for Efficient Installation

Introducing the Aohuan Bright Shell Series Heavy Gauge Pipe Fitting Covers, expertly crafted to accommodate various pipe fittings for both industrial and commercial applications. Our covers, including the 90° Short Radius Elbows, are designed with one-piece welded construction, ensuring quick and easy installation in the field while providing long-lasting maintenance simplicity. As a leading supplier from China, our factory prioritizes quality and durability, making our pipe fitting covers the ideal choice for your next project.

    Installation Video

    Product Reference Guide

    1. Code Example: AES02
    A — Company brand
    ES — 90° short radius elbow
    02 — Product mold number
    D — Pipe outer diameter
    2. Selection Principle
    According to the chart, select the corresponding pipe diameter and insulation thickness. The chart shows the combined dimensions. Suitable for short and long radii Threads and welding elbows.
    3. Custom Specifications
    Special specifications can be emailed to contact manufacturers to customize.
    4. Colour Options:
    COLOR
    Standard Color Reference Chart

    Product Specifications

    Number D (mm) Inch Scope of Application (Outer Diameter + Insulation) Number D (mm) Inch Scope of Application (Outer Diameter + Insulation)
    AES02 42 1 2/3 - AES18 141 5 5/9 102*20 89*25 83*30 60*40 43*50 22*60
    AES03 48 1 8/9 - AES19 149 5 7/8 108*20 89*30 70*40 48*50 28*60
    AES04 54 2 1/8 13*20 AES20 155 6 1/9 114*20 102*25 76*40 54*50
    AES05 60 2 3/8 22*20 13*25 AES21 168 6 5/8 127*20 114*25 108*30 89*40
    AES06 67 2 5/8 28*20 16*25 - - - 70*50 48*60
    AES07 73 2 7/8 32*20 22*25 13*30 AES22 180 7 1/9 140*20 127*25 102*40 76*50 60*60
    AES08 79 3 1/9 35*20 28*25 16*30 AES23 193 7 3/5 140*25 134*30 114*40 76*60
    AES09 82 3 2/9 42*20 34*25 22*30 AES24 208 8 1/5 168*20 159*25 127*40 108*50 89*60
    AES10 89 3 1/2 48*20 28*30 AES25 219 8 5/8 168*25 159*30 140*40 114*50
    AES11 98 3 6/7 57*20 48*25 34*30 13*40 AES26 232 9 1/8 159*40 134*50 114*60
    AES12 102 4 60*20 54*25 42*30 22*40 AES27 245 9 5/8 168*40 140*50 127*60
    AES13 108 4 1/4 70*20 60*25 48*30 28*40 AES28 258 10 1/6 159*50 140*60
    AES14 116 4 4/7 76*20 64*25 57*30 48*32 35*40 13*50 AES29 279 11 169*50
    AES15 122 4 4/5 70*25 60*30 57*32 42*40 22*50 AES30 299 11 7/9 219*40
    AES16 127 5 89*20 76*25 64*30 57*35 48*40 24*50 AES31 323 12 5/7 219*50
    AES17 136 5 3/8 76*30 57*40 34*50 13*60 AES32 339 13 1/3 219*60

    Technical Support

    Aohuan provides insulation and external protection not only with high-quality composite PVC external protection system material products, but also with its rich experience in the market of installation and application of insulation external protection and advanced application programs.
    1
    Choose the most suitable thermal insulation and external protection system based on the specific working conditions.
    2
    Technical Reform of Existing Thermal Insulation and External Protection.
    3
    A brand-new tailored heat preservation and exterior protection product with special-shaped structure.
    4
    Product Maintenance Training.

    Physical Properties

    Performance Basis of Testing Testing Result
    Flame ASTM E84 ≤25
    Smog ASTM E84 ≤50
    Specific gravity ASTM 792 1.46
    Anti-swelling strength ASTM D638 7,000 (@yield lb/in²)
    Tensile capacity ASTM D638 400,000 (PSI)
    Pendulum impact ASTM D256 15.0 (ft.lb.in)
    Aging property ASTM E96 0.03 (@0.30")
    Conductivity ASTM D257 Nil
    Anaerobic index GB /T2406.2-2009 33.1%
    Service life Actual life of use > 10 years

    Area of Application

    Aohuan composite PVC-based material forming and exterior protection materials can be widely applied in commercial, industrial and civil both indoor and outdoor; The exterior protective material of composite PVC base material is suitable for various pipelines and equipment exterior protective systems with temperature ranging from – 37 ℃ to 260 ℃ , but the exterior surface temperature of insulation layer is lower than 66 ℃ (the national standard is lower than 50 ℃ ).
    Sector 1
    Microelectronics, Photovoltaic, Food, Beverage, Light Industry.
    Sector 2
    Biopharmaceutical, Commercial, Civil Building, Oil Drilling Platform.
    Sector 3
    External Insulation of Petroleum, Chemical Industry, Newly Built and Reconstructed Industrial Workshops and Tanks.

    Frequently Asked Questions

    Q: What do the product reference codes (such as AES02) stand for?
    The product code stands for specific product configurations. For example, in AES02: A represents the company brand, ES indicates a 90° short radius elbow, 02 is the unique product mold number, and D refers to the pipe's outer diameter.
    Q: How do I select the correct pipe diameter and insulation thickness?
    You should refer directly to our specification chart to match your requirements with the corresponding pipe diameter and insulation thickness. The chart presents combined dimensions suitable for both short and long radii threads as well as welding elbows.
    Q: Can I request custom specifications for Aohuan products?
    Yes, absolutely. For any special or non-standard specifications, you can contact the manufacturers directly via email to request customized product solutions tailored to your project.
    Q: What technical support does Aohuan offer to its customers?
    Aohuan provides comprehensive technical support including: selecting the optimal insulation and external protection systems for specific working conditions, technical reconstruction of existing external protection systems, designing brand-new tailored structures, and providing specialized product maintenance training.
    Q: What is the service life and temperature range of Aohuan composite PVC protective systems?
    Our materials are highly durable with an actual service life exceeding 10 years. They are suitable for pipeline and equipment systems operating between –37 ℃ and 260 ℃, provided that the exterior surface temperature of the insulation layer remains below 66 ℃ (with a national standard limit of below 50 ℃).

    Leave Your Message