China Suppliers Factory 90° Short Radius Elbow Industrial Insulation Pipe Fitting Covers for Efficient Installation
Installation Video
Product Reference Guide
1. Code Example: AES02
A — Company brand
ES — 90° short radius elbow
02 — Product mold number
D — Pipe outer diameter
2. Selection Principle
According to the chart, select the corresponding pipe diameter and insulation thickness. The chart shows the combined dimensions. Suitable for short and long radii Threads and welding elbows.
3. Custom Specifications
Special specifications can be emailed to contact manufacturers to customize.
4. Colour Options:
Standard Color Reference Chart
Product Specifications
| Number | D (mm) | Inch | Scope of Application (Outer Diameter + Insulation) | Number | D (mm) | Inch | Scope of Application (Outer Diameter + Insulation) |
|---|---|---|---|---|---|---|---|
| AES02 | 42 | 1 2/3 | - | AES18 | 141 | 5 5/9 | 102*20 89*25 83*30 60*40 43*50 22*60 |
| AES03 | 48 | 1 8/9 | - | AES19 | 149 | 5 7/8 | 108*20 89*30 70*40 48*50 28*60 |
| AES04 | 54 | 2 1/8 | 13*20 | AES20 | 155 | 6 1/9 | 114*20 102*25 76*40 54*50 |
| AES05 | 60 | 2 3/8 | 22*20 13*25 | AES21 | 168 | 6 5/8 | 127*20 114*25 108*30 89*40 |
| AES06 | 67 | 2 5/8 | 28*20 16*25 | - | - | - | 70*50 48*60 |
| AES07 | 73 | 2 7/8 | 32*20 22*25 13*30 | AES22 | 180 | 7 1/9 | 140*20 127*25 102*40 76*50 60*60 |
| AES08 | 79 | 3 1/9 | 35*20 28*25 16*30 | AES23 | 193 | 7 3/5 | 140*25 134*30 114*40 76*60 |
| AES09 | 82 | 3 2/9 | 42*20 34*25 22*30 | AES24 | 208 | 8 1/5 | 168*20 159*25 127*40 108*50 89*60 |
| AES10 | 89 | 3 1/2 | 48*20 28*30 | AES25 | 219 | 8 5/8 | 168*25 159*30 140*40 114*50 |
| AES11 | 98 | 3 6/7 | 57*20 48*25 34*30 13*40 | AES26 | 232 | 9 1/8 | 159*40 134*50 114*60 |
| AES12 | 102 | 4 | 60*20 54*25 42*30 22*40 | AES27 | 245 | 9 5/8 | 168*40 140*50 127*60 |
| AES13 | 108 | 4 1/4 | 70*20 60*25 48*30 28*40 | AES28 | 258 | 10 1/6 | 159*50 140*60 |
| AES14 | 116 | 4 4/7 | 76*20 64*25 57*30 48*32 35*40 13*50 | AES29 | 279 | 11 | 169*50 |
| AES15 | 122 | 4 4/5 | 70*25 60*30 57*32 42*40 22*50 | AES30 | 299 | 11 7/9 | 219*40 |
| AES16 | 127 | 5 | 89*20 76*25 64*30 57*35 48*40 24*50 | AES31 | 323 | 12 5/7 | 219*50 |
| AES17 | 136 | 5 3/8 | 76*30 57*40 34*50 13*60 | AES32 | 339 | 13 1/3 | 219*60 |
Technical Support
Aohuan provides insulation and external protection not only with high-quality composite PVC external protection system material products, but also with its rich experience in the market of installation and application of insulation external protection and advanced application programs.
1
Choose the most suitable thermal insulation and external protection system based on the specific working conditions.
2
Technical Reform of Existing Thermal Insulation and External Protection.
3
A brand-new tailored heat preservation and exterior protection product with special-shaped structure.
4
Product Maintenance Training.
Physical Properties
| Performance | Basis of Testing | Testing Result |
|---|---|---|
| Flame | ASTM E84 | ≤25 |
| Smog | ASTM E84 | ≤50 |
| Specific gravity | ASTM 792 | 1.46 |
| Anti-swelling strength | ASTM D638 | 7,000 (@yield lb/in²) |
| Tensile capacity | ASTM D638 | 400,000 (PSI) |
| Pendulum impact | ASTM D256 | 15.0 (ft.lb.in) |
| Aging property | ASTM E96 | 0.03 (@0.30") |
| Conductivity | ASTM D257 | Nil |
| Anaerobic index | GB /T2406.2-2009 | 33.1% |
| Service life | Actual life of use | > 10 years |
Area of Application
Aohuan composite PVC-based material forming and exterior protection materials can be widely applied in commercial, industrial and civil both indoor and outdoor; The exterior protective material of composite PVC base material is suitable for various pipelines and equipment exterior protective systems with temperature ranging from – 37 ℃ to 260 ℃ , but the exterior surface temperature of insulation layer is lower than 66 ℃ (the national standard is lower than 50 ℃ ).
Sector 1
Microelectronics, Photovoltaic, Food, Beverage, Light Industry.
Sector 2
Biopharmaceutical, Commercial, Civil Building, Oil Drilling Platform.
Sector 3
External Insulation of Petroleum, Chemical Industry, Newly Built and Reconstructed Industrial Workshops and Tanks.
Frequently Asked Questions
Q:
What do the product reference codes (such as AES02) stand for?
The product code stands for specific product configurations. For example, in AES02: A represents the company brand, ES indicates a 90° short radius elbow, 02 is the unique product mold number, and D refers to the pipe's outer diameter.
Q:
How do I select the correct pipe diameter and insulation thickness?
You should refer directly to our specification chart to match your requirements with the corresponding pipe diameter and insulation thickness. The chart presents combined dimensions suitable for both short and long radii threads as well as welding elbows.
Q:
Can I request custom specifications for Aohuan products?
Yes, absolutely. For any special or non-standard specifications, you can contact the manufacturers directly via email to request customized product solutions tailored to your project.
Q:
What technical support does Aohuan offer to its customers?
Aohuan provides comprehensive technical support including: selecting the optimal insulation and external protection systems for specific working conditions, technical reconstruction of existing external protection systems, designing brand-new tailored structures, and providing specialized product maintenance training.
Q:
What is the service life and temperature range of Aohuan composite PVC protective systems?
Our materials are highly durable with an actual service life exceeding 10 years. They are suitable for pipeline and equipment systems operating between –37 ℃ and 260 ℃, provided that the exterior surface temperature of the insulation layer remains below 66 ℃ (with a national standard limit of below 50 ℃).